SLEEKFENCE™ Project Application Chart

The tables below are intended as general guidelines for fence post installations. For all projects, certified engineering shall be required before purchase or installation. Extreme weather design, local building departments requirements, or unique site-specific conditions may affect the information presented below. Consult a locally licensed design professional and other relevant advisors for your specific installation.

Enter your project address in the link below, to determine your design wind speed (use risk category II speeds).

https://ascehazardtool.org/

Fence Post Mounting Option #1: Dig & Set Post
6063-T6 Aluminum Post (with 16 GA, A36 Steel Insert Where Indicated) Embedded in Concrete Footings
EXPOSURE C (DEFAULT)
MAXIMUM ULTIMATE WIND SPEED (3-SEC GUST)
Wind Speed 46 IN 60 IN 69 IN 84 IN 96 IN 108 IN 120 IN
90 MPH (145 KMH)POSTPOSTPOSTPOSTPOSTPOST+ INS
100 MPH (161 KMH)POSTPOSTPOSTPOST+ INS+ INS+ INS
120 MPH (194 KMH)POSTPOSTPOST+ INS+ HD INS+ HD INS+ HD INS
140 MPH (226 KMH)POSTPOSTPOST+ HD INS+ HD INS+ HD INS+ HD INS
160 MPH (258 KMH)POSTPOST+ INS+ HD INS+ HD INS+ HD INS+ HD INS
EXPOSURE D (COASTAL)
MAXIMUM ULTIMATE WIND SPEED (3-SEC GUST)
Wind Speed 46 IN 60 IN 69 IN 84 IN 96 IN 108 IN 120 IN
90 MPH (145 KMH)POSTPOSTPOSTPOSTPOST+ INS+ HD INS
100 MPH (161 KMH)POSTPOSTPOSTPOST+ INS+ HD INS+ HD INS
120 MPH (194 KMH)POSTPOST+ INS+ INS+ HD INS+ HD INS+ HD INS
140 MPH (226 KMH)POSTPOST+ INS+ HD INS+ HD INS+ HD INS+ HD INS
160 MPH (258 KMH)POST+ INS+ HD INS+ HD INS+ HD INS+ HD INS+ HD INS
POST = Post alone shall have sufficient strength for Dig & Set installation under this condition.
+INS = Post shall require 16GA Steel C-Channel insert addition to reach required strength for this condition.
+HD INS = Standard 16GA insert is not strong enough for this installation condition. Site-specific heavy-duty engineered post inserts are required.
Concrete footing size and reinforcement requirements shall be calculated separately on a site-specific basis.
Fence Post Mounting Option #2: Direct Concrete Mount
6063-T6 Aluminum Post with steel insert welded to baseplate (Anchored to concrete host)
EXPOSURE C (DEFAULT)
MAXIMUM ULTIMATE WIND SPEED (3-SEC GUST)
Wind Speed 46 IN 60 IN 69 IN 84 IN 96 IN 108 IN 120 IN
90 MPH (145 KMH)1/8"1/8"1/8"1/8"1/8"1/8"3/16"
100 MPH (161 KMH)1/8"1/8"1/8"1/8"3/16"3/16"3/16"
120 MPH (194 KMH)1/8"1/8"1/8"3/16"3/16"1/4"1/4"
140 MPH (226 KMH)1/8"1/8"1/8"3/16"1/4"1/2"1/2"
160 MPH (258 KMH)1/8"1/8"3/16"1/4"1/2"1/2"N/A
EXPOSURE D (COASTAL)
MAXIMUM ULTIMATE WIND SPEED (3-SEC GUST)
Wind Speed 46 IN 60 IN 69 IN 84 IN 96 IN 108 IN 120 IN
90 MPH (145 KMH)1/8"1/8"1/8"1/8"1/8"3/16"3/16"
100 MPH (161 KMH)1/8"1/8"1/8"1/8"3/16"3/16"1/4"
120 MPH (194 KMH)1/8"1/8"1/8"3/16"3/16"1/4"1/2"
140 MPH (226 KMH)1/8"1/8"3/16"1/4"1/2"1/2"N/A
160 MPH (258 KMH)3/16"3/16"3/16"1/2"1/2"N/AN/A
Steel post insert height to be 12″ for 1/8″ thickness inserts. Inserts thicker than 1/8″ shall require separate engineering to determine height.

Concrete footing, slab, or host structure size and applicability shall be calculated on a site-specific basis. Surface attachment requirements shall be calculated on a site-specific basis. Baseplate size, orientation, and utilized anchors may vary with site-specific project parameters and availability.

Installation Video

Mounting Channel to Post & Panel Screw Spacing
Screw spacing applicable for all fence heights
Use #12. Self-drilling screw through mounting channel into panel and post (and post insert)
MAXIMUM ULTIMATE WIND SPEED
(3-SEC GUST)
EXPOSURE C (DEFAULT)
SCREW SPACING (INCHES, O.C)
EXPOSURE D (COASTAL)
SCREW SPACING (INCHES, O.C)
90 MPH (145 KMH)24"24"
100 MPH (161 KMH)24"24"
120 MPH (194 KMH)24"20"
140 MPH (226 KMH)20"16"
160 MPH (258 KMH)16"12"

ONLINE TABLE NOTES:

Information presented above shall be for general reference of SLEEKFENCE™ systems and does not constitute a site-specific project design.

Before project fabrication and installation, fence system shall be reviewed on a site-specific basis, and include a certified Engineer’s drawing.

Fence post calculations consider a 6′ 4″ O.C. Maximum Post Spacing. Greater wind speeds & design conditions may be achievable with shorter post spacing.

Existing host structure suitability for fence attachment shall be determined by the Structural Engineer on a site-specific basis.

Fences used as life-safety guardrails (Adjacent to dropoffs greater than 30″) and surrounding pools are subject to additional codes and requirements.

Visit Engineeringexpress.com/wind to learn more about Ultimate Wind Speed, Risk Category, and Exposure Category.

Please don’t hesitate to Contact Us if you have any questions about this report or your project application.

Our product warranty is subject to the use of our products in their correct application, installation, and our Terms and Conditions.

The terms of our warranty are set out in our Limited Lifetime Aluminum Fence Warranty.